Technical description
The control box is built to electrical apparatus protection class II, double insulated and mounted in an ABS casing. The control box operates with an anode staff equipped with a dead-man’s switch. There cannot be voltage at the anode unless the dead-man’s switch is pressed. The control box includes monitoring to ensure that the voltage is cut off if the dead-man’s switch is not pressed. The control box has automatic fuses, mounted under a hinged lid so that they can easily be reset.
SE 500 is built to work together with a 3-phase 400 V generator, and SE 300 with a 230 V generator. The control box produces pure DC voltage.
SE 300 technical data
The SE 300 is used for wading fishing in smaller watercourses.
Control box | |
Input voltage | 230 V AC, 50 Hz |
Input current, maximum | 13 A |
Output voltage | 300 V DC |
Maximum ripple voltage | 4 V |
Output current, maximum | 10 A DC |
Control voltage for the dead-man’s switch | 24 V AC |
Size (mm) (length x width x height) | 400 x 210 x 310 |
Weight | 7.4 kg |
Waterproofing class | IP 55 |
Anode staff | |
Ring* diameter | 300* mm stainless steel |
Staff | 1 300* mm long, 26 mm fiberglass tube** |
Staff weight | 0.79 kg |
Cable | 52 m |
Cable weight | 3.7 kg (0.072 kg/m) |
Cathode grid | |
Grid | 320 x 320* mm copper grid |
Cable | 8* m |
Recommended generator | 1 500 to 3 000 W |
SE 500 technical data
The SE 500 is used for fishing in large watercourses.
Control box | |
Input voltage | 3 x 400 V AC, 50 Hz |
Input current, maximum | 7.2 A |
Output voltage | 500 V DC |
Maximum ripple voltage | 13 V |
Output current, maximum | 10 A DC |
Control voltage for the dead-man’s switch | 24 V AC |
Size (mm) (length x width x height) | 400 x 210 x 310 |
Weight | 7.7 kg |
Waterproofing class | IP 55 |
Anode staff | |
Ring* diameter | 600* mm stainless steel |
Staff | 2 300* mm long, 30 mm fiberglass tube** |
Staff weight | 1.6 kg |
Cable | 8* m |
Cable weight | 0.72 kg (0.090 kg/m) |
Cathode grid | |
Grid | 500 x 500* mm copper grid |
Cable | 8* m |
Recommended generator | 5 000 to 7 000 W |
Customization
*The anode shape, size, staff length, the cable lengths and the cathode grid size can be customised, according to the customer’s requirements. If required by local conditions, the anode can be removed from the staff and a larger or smaller anode can be fitted. An oval or rectangle (these may be better for very low water) can be supplied instead of a ring.
**Two anode staffs, and a control box capable of feeding them, can be supplied, if the customer requires this. If two anode staffs are used, the dead-man’s switch must be pressed on both of them to have voltage between the cathode and the anodes. A blind plug is supplied with this configuration, and if the blind plug is plugged into the control box, the electrofisher can be used with only one anode staff.
DTU report
Click here to download the Danish Technical University report on the Stampes Elektro Electrofisher (only available in Danish).
CE certification
Download brochure
Click here to download the SE 300 and SE 500 brochure.